Type Message Location Additional Information Action
35 PS-BOOST BOARD FAULT
A PS-BOOST board problem
has been detected
CPU (80) INFO 0 = type of error (1 = more
than one boost present or boost in
a small rack; 2 = no boost nor ex-
ternal feeding; 3 = external power
loss; 4 = external power recovery)
36 The status of the server certific-
ate has changed
INFO 0
- 1: Certificate OK
- 2: Incomplete names list
- 3: Expired certificate
- 4: Expired authority
INFO1 = Type of certificate
- 0: Self-signed
- 1: CA-signed
INFO2 = Trigger
- 0: Reset
- 1: Webdiag
- 2: Config
- 3: Daily check
39 R_PASSWORD_AUTHENTICA
TION_LOCKED
User password authentication is
currently locked for Remote/Loc-
al access to WSAPI and VMU
Board loca-
tion
INFO 0 = Reason for lock
- 01 = Local access to VMU
- 02 = Remote access to VMU
- 03 = Local access to WSAPI
- 04 = Remote access to WSAPI
INFO 1 = Count of lock
INFO 2 = First byte of EDN
INFO 3 = Second byte of EDN
40 R_ANO_EMERGENCY_CONFI
G
No device has been configured
to receive emergency call noti-
fication
41 R_PASSWORD_AUTHENTICA
TION_UNLOCKED
User password authentication is
currently unlocked for Remote/
Local access to WSAPI and
VMU
Board loca-
tion
INFO 0 and 1 = Not used
INFO 2 = First byte of EDN
INFO 3 = Second byte of EDN
44 R_ARP_SPOOF_INFO
ARP spoofing detected. Multiple
ARP reply received within lock-
time period.
Board loca-
tion
INFO 0 to 3 = IP address of the tar-
get, eg : C0 A8 5C 16 for
192.168.92.22
45 R_MGTSRV_LOCK
Access to system management
is locked due to 6 consecutive
authentication failures with in 5
minutes.
Board loca-