EasyManua.ls Logo

Alcatel-Lucent OmniPCX Office

Alcatel-Lucent OmniPCX Office
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Type Message Location Additional Information Action
148 REGISTER FAILED
SIP registration failure
CPU (80) INFO 0 = octet 1 of the IP address
of the remote registry
INFO 1 = octet 2 of the IP address
of the remote registry
INFO 2 = octet 3 of the IP address
of the remote registry
INFO 3 = octet 4 of the IP address
of the remote registry
149 SIP Registration rejected CPU (80) INFO 0 = reason for the rejection
- 0: Undefined error
- 1: Unknown user
- 2: No request or Registrar call
- 3: Bad login or username
- 4: Bad password
- 5: Bad domain name
- 6: Error processing of register
request
- 7: Only one contact allowed.
- 8: Database full
- 9: Too many contacts for one
single address
10: Wrong terminal type for IP-
DECT handset
INFO 1 = First byte of edn
INFO 2 = Second byte of edn.
INFO 3 = Count of occurrence of
the event with same reason of re-
ject
150 R_
ANO_QUARANTINE_ALERT
CPU (80) An IP address has been placed in
quarantine.
The IP address placed in quarant-
ine can be one of a SIP Phone or of
a Gateway SIP Trunk.
The four bytes of the IP address are
given in comp_info[0],
comp_info[1], comp_info[2] and
comp_info[3].
160 THRESHOLD HARDWARE TA-
BLE
The critical threshold (80 % by
default) of the hardware fault ta-
ble has been reached
CPU (80)
161 THRESHOLD HISTORY TA-
BLE
The critical threshold (80 % by
default) of the history fault table
has been reached
CPU (80)
Chapter
6
% *
38/62
 ! "#$ ! % $& !     

Other manuals for Alcatel-Lucent OmniPCX Office