Reject reasons for interfaces Meaning
25: REJ_MAX_IBS Maximum of IBS reached for a reached
26: REJ_MAX_WIRED_MAIN_DEV_PER_S Maximum of wired main devices reached
27: REJ_NIL_DYN_PROT Default allocated protocol is not NIL_PROT
28: REJ_MAX_POWER_BUDGET Maximum of power budget reached for a cab-
inet
29: REJ_MAX_HSL_LINK_TS Maximum of hsl resources reached for a cab-
inet
30: REJ_MAX_HDLC_RESOURCE Maximum of hdlc resource reached for the
system
31: REJ_LICENSE EXCEEDED Maximum of B channels reached
32: REJ_LIN_INIT_FAILED LIN init failed
33: REJ_B_CH_INIT_FAILED B channel init failed
34: REJ_MAX_AT_PER_CAB Maximum of analog trunk reached for a cab-
inet
35: REJ_MAX_AT_PER_SYS Maximum of analog trunk reached for the sys-
tem
36: REJ_MAX_RESSOURCE_REACHED Maximum of ressource reached (when limita-
tion)
37: REJ_PROTOCOL_NOT_SUPPORTED Protocol mismatch
6.5.8 Software key states (INFO 1 of message 34)
01 : system boot; the current key does not correspond to the system (wrong serial number):
the services are open for a limited time.
02 : system booted with a valid key.
03 : system booted with a key problem. The services are closed.
04 : system boot; the current key version does not correspond to the system software version:
the services are open for a limited time.
05 : system boot; the current key version does not correspond to the system software version;
the end of the limited period causes the services to close.
06 : system boot; the current key is too old; the services are open for a limited time.
07 : system boot; the current key is too old; the end of limited time causes the services to
close.
12 : valid key entered.
13 : the current key does not correspond to the system (invalid serial number); end of limited
time causes the services to close.
14 : serial number problem with the system key; a new key with a valid serial number but with
a version which does not correspond to system software version has been entered: the
services are open for a limited time.
16 : serial number problem with the system key; a new key with a correct serial number but too
old has been entered: the services are open for a limited time.
% *
 ! "#$ ! % $& !     