IMPORTANT INFORMATION
• Always drain the Alde Compact 3020 and Alde Flow of fresh water when there is a risk of frost and when the vehicle is
not being used.
MAINTAINING THE ALDE FLOW
Repairs shall be performed by a qualied service technician. Verify proper operation after servicing.
TROUBLESHOOTING
No continuous hot water
• Hot Water Boost automatically deactivates after 30 minutes. Activate Hot Water Boost again.
• Check that “Alde Flow” is ticked in Installed Accessories Menu. The tank symbol will appear in the Standby Screen
when Hot Water Boost is activated.
• Bleed the system of air.
• Check that the Alde Flow’s 12 V circulation pump is connected to the options dongle correctly.
• Check that both gas and electric heating are selected and functioning.
• Check that the Alde Flow’s 12 V circulation pump has 12 V power and is functioning.
“Alde Flow” does not appear in Installed Accessories Menu
• Check that the options dongle is connected to the Alde 3020 Compact HE boiler
• Disconect and then reconect the 12 V power supply to the Compact 3020 after connecting the option dongle to
reboot the settings..
Noise from Alde Flow’s 12 V circulation pump
• Bleed the system of air.
There comes no water despite the fact that the tap is open
• Check that the vehicles fresh water pump is on.
• Check that there is no ice plugs in water tank or pipes.
• Check that all draining valves / FrostControl are closed.
• Check that the vehicle’s water pump is functioning and there is a supply of water.
The “Alde Flow” symbol ashes
• The water is in the process of being heated. The symbol changes to being permanently lit when the temperature
reaches 140°F (60°C).
6