Notice de Montage
www.aldes.com
Cube 300 et 370 micro-watt
VMC double flux
GB
p. 25
D
S. 49
NL
p. 73
I
p. 97

Table of Contents

Questions and Answers

  • K
    Kayla CobbAug 9, 2025
    How to fix aldes Dee Fly Cube 300 micro-watt Fan when the "Filter" light is lit?
    • A
      Ashley FordAug 9, 2025
      If the 'Filter' light is lit on your aldes Fan, it indicates that the filters need to be replaced. Replace the filters and then press the “filter” button.
  • H
    Holly StewartAug 14, 2025
    What to do if the Fault Light is lit on my aldes Fan?
    • E
      Elizabeth FryeAug 15, 2025
      If the Fault light is lit on your aldes Fan, there may be a problem with the motors. Turn the unit off for 30 seconds and then reset it. If the product does not restart, it may indicate a problem with the temperature sensors, and you should contact your installer.
  • R
    rdavidAug 19, 2025
    Why is my aldes Dee Fly Cube 300 micro-watt system so noisy?
    • B
      Brian OwensAug 19, 2025
      If your aldes Fan system is noisy, it could be due to several reasons: * The ductwork might be crushed or have too many bends, so check the ducts. * The system might be incorrectly configured for the house, so check the configuration of the unit. * The filters might be clogged, so replace the filters.
  • M
    Michael ChapmanAug 25, 2025
    What to do if my aldes Fan is making a dripping noise?
    • C
      Cody TorresAug 25, 2025
      If you hear a dripping noise from your aldes Fan, it could be due to a couple of reasons: * The water trap may not be working, so check that there is water in the water trap. * The water drainage pipe may be blocked, so unblock the pipe.
  • M
    mckenziekennedyAug 29, 2025
    What to do if my aldes Dee Fly Cube 300 micro-watt Fan unit does not start?
    • C
      Crystal DelgadoAug 29, 2025
      If the unit does not start, there are several potential causes: * The hygro grille might be badly referenced, so use the BUS hygro grille. * There might be a false contact with the BUS link, so check the link cable. * The waiting time may be too short, so wait between 30 seconds and 1 minute before turning it on.
  • K
    Kristina WolfeSep 3, 2025
    Why are there low airflow levels at the grilles of my aldes Dee Fly Cube 300 micro-watt Fan?
    • P
      pamela59Sep 3, 2025
      If you're experiencing low airflow levels at the grilles of your aldes Fan, it could be due to: * Ducts that are incorrectly balanced, so check the lengths of the duct branches. * Leaks in the ducts, so make sure the ducts are correctly sealed.