Maintenance: The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.
MAXIMUM NUMBER OF CONNECTABLE SMOKE DETECTORS:
It is recommended to register a maximum of 9 smoke detectors on each other.
Please note that the smoke detectors within a maximum radius of 20M from where an alarm comes from will sound.
Plan an escape route:
Make a map and mark all locations of doors and windows and a possible escape route. Note that you may need an escape ladder on high floors.
Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the escape route.
Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond quickly. If you do not notice smoke or heat,
check if everyone in the house is in a secure location.
Do not open any doors without feeling wether the door is warm or if there is smoke coming from underneath the doors. If it is, do not open that
door. If the door is cold, put your shoulder firmly against the door and open it a small amount to check for any heat or smoke first.
If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire department as soon as you are safe
outside.
Replacing the batteries: The detectors are supplied using 2x AA batteries. Only use the recommended types:
- Energizer E91
- Gold Peak Group GP15A
- Raymax LR6
Under normal conditions the battery will last at least one year. If it is about to need replacement, the smoke detector will make a chirping sound every
40 seconds for at least 30 days. Pay attention to the polarity when replacing batteries. Test the detector after every battery replacement. If the smoke
detector does not function, please contact your supplier.
Environment: Do not throw away used batteries, but recycle them using your local chemical depot.
Product may not be thrown out as normal waste, but must be recycled as electrical waste.
Connect / Test / Time-out-button
Press for: Lamp
Start connection mode 12 seconds On
Connect to a nearby device in connec-
tion mode
0,5 second Fast blinking
Time-out 0,5 second Blinks every 8 seconds
Normal operation - Blinks every 50 seconds
Test single smoke alarm 3 seconds Blinks slowly + beeps
Test all smoke alarms 30-90 seconds Blinks slowly + alarms
Other smoke alarms:
Blinks slowly + beeps
OVERVIEW OF KEY FUNCTIONS: