Do you have a question about the Alfa Laval REMIND EPC 50 and is the answer not in the manual?
Brand | Alfa Laval |
---|---|
Model | REMIND EPC 50 |
Category | Control Unit |
Language | English |
Details PC specifications for REMIND™ EPC 50 Network, including processor, RAM, OS, and ports.
Step-by-step guide on installing REMIND™ EPC 50 software from diskettes, including dialog box interactions.
Specifies requirements for SattBus cable length, impedance, and termination resistors for EPC 50 systems.
Explains how the PC connects to EPC 50 Control Cabinets via SattBus, detailing two alternative methods.
Describes connecting a PC to EPC 50 Control Cabinets using a SattBus PC board, with step-by-step instructions.
Details connecting a PC to EPC 50 Control Cabinets using a SattBus Serial Unit (SBSU) via serial port.
Explains how to set unique node addresses for EPC 50 units on the SattBus network for proper communication.
Instructions on how to physically connect the SattBus cable between EPC 50 units via I/O board connectors.
Describes how to view available nodes on the SattBus network using the EPC50 Operator's panel.
Troubleshooting steps for establishing communication with EPC network using a PC board, focusing on common problems.
Troubleshooting steps for establishing communication with EPC network using the SBSU unit, addressing power, connections, and LEDs.
Provides diagrams and article numbers for the 24 VDC power supply and the serial communication cable.
Describes the layout of the SattBus PC-board and how to configure its main components and switches.
Details the physical construction and mounting options for the SBSU unit, including dimensions and protection class.
Lists and explains the function and color of the LEDs on the SBSU unit for status indication.
Describes the function of the hex and DIP switches on the SBSU unit for configuration.
Covers the installation process for the SBSU unit, including power, grounding, and network connections.
Specifies how to connect the 24 V DC power supply and grounding for the SBSU unit.
References the general SattBus installation guidelines for connecting the SBSU to the network.
Details the serial channel connection for the SBSU, including D-type connectors and cable requirements.
Explains how to configure the SBSU unit using its switches for node identity, filter address, and mode.
Describes setting the unique node address for each SBSU unit using hexadecimal switches.
Explains how to set filter addresses on the SBSU for bridge configuration using hexadecimal switches.
Details the function and setting of the mode switch on the SBSU unit.
Describes setting serial channel parameters like baud rate, parity, and modem delay on the SBSU.