PowerFlex 750-Series Products with TotalFORCE Control 9
Rockwell Automation Publication 750-PC100A-EN-P - December 2016
900 Hp 9 1135 Light 20x…D1K0 1249 – 1044 – 2000 – 1500 1900 1500 3500 1500 3000 1500 1253 1400 4
1045 Normal 1150 1568 961 – 2000 – 1350 1800 1350 3000 1350 2500 1350 1154 1400 4
960 Heavy 1440 1728 883 – 2000 – 1200 1600 1200 3000 1200 2400 1200 1060 1400 4
1000 Hp 9 1365 Light 20x…D1K1 1502 – 1256 – 2000 – 1800 2400 1800 4000 1800 3500 1800 1507 1400 4
1135 Normal 1249 1703 1044 – 2000 – 1500 1900 1500 3500 1500 3000 1500 1253 1400 4
1045 Heavy 1568 1881 961 – 2000 – 1350 1800 1350 3000 1350 2500 1350 1154 1400 4
1100 Hp 9 1520 Light 20x…D1K3 1672 – 1398 – 2000 – 1900 2500 1900 4500 1900 3800 1900 1678 1400 4
1365 Normal 1502 2048 1256 – 2000 – 1800 2400 1800 4000 1800 3500 1800 1507 1400 4
1135 Heavy 1703 2043 1044 – 2000 – 1500 1900 1500 3500 1500 3000 1500 1253 1400 4
1250 Hp 10 1655 Light 20x…D1K4 1821 – 1522 – 2000 1250 2400 3000 2400 5000 2400 4000 2400 1827 1400 6
1420 Normal 1562 2130 1306 – 2000 1250 1800 2400 1800 4000 1800 3500 1800 1568 1400 6
1365 Heavy 2048 2457 1256 – 2000 1250 1800 2400 1800 4000 1800 3500 1800 1507 1400 6
1500 Hp 10 2070 Light 20x…D1K6 2277 – 1904 – 2000 1250 3000 3500 3000 6000 3000 5000 3000 2285 1400 6
1655 Normal 1821 2483 1522 – 2000 1250 2400 3000 2400 5000 2400 4000 2400 1827 1400 6
1420 Heavy 2130 2556 1306 – 2000 1250 1800 2400 1800 4000 1800 3500 1800 1568 1400 6
1800 Hp 10 2240 Light 20x…D2K0 2464 – 2060 – 2000 1250 3000 4000 3000 6000 3000 5000 3000 2473 1400 6
2072 Normal 2279 3108 1906 – 2000 1250 3000 3500 3000 6000 3000 5000 3000 2288 1400 6
1655 Heavy 2483 2979 1522 – 2000 1250 2400 3000 2400 5000 2400 4000 2400 1827 1400 6
2400 Hp 11 2960 Light 20x…D2K6 3256 – 2723 2000 2000 – 3800 5000 3800 6000 3800 6000 3800 3268 1400 8
2738 Normal 3012 4107 2519 2000 2000 – 3500 4500 3500 6000 3500 6000 3500 3023 1400 8
2240 Heavy 3360 4032 2060 2000 2000 – 3000 3800 3000 6000 3000 5000 3000 2473 1400 8
3000 Hp 12 3696 Light 20x…D3K4 4066 – 3400 2000 2000 1250 5000 6000 5000 6000 5000 6000 5000 4081 1400 10
3404 Normal 3744 5106 3131 2000 2000 1250 4500 6000 4500 6000 4500 6000 4500 3758 1400 10
2980 Heavy 4470 5364 2741 2000 2000 1250 3800 5000 3800 6000 3800 6000 3800 3290 1400 10
(1) ‘Applied Rating’ refers to the motor that will be connected to the drive. For example, a ‘D430’ drive can be used in Normal Duty mode on a 350 Hp motor, in Heavy Duty mode on a 300 Hp motor or in Light Duty mode on a 400 Hp motor. The drive can be programmed for each mode. Wiring and fuses can be sized
based on the programmed mode. For any given drive catalog number, Normal Duty mode provides higher continuous current but smaller overload current with respect to Heavy Duty mode. See parameter 306 [Duty Rating].
Refer to Specifications for an explanation of Duty Ratings.
(2) These AC line fuses (with blown fuse indicators) are included in the drive to provide drive short circuit protection. AC input protection devices for branch circuit protection based on US NEC are listed in the table. Each LCL filter has one fuse per phase.
(3) Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping.
(4) Maximum protection device size is the highest rated device that supplies drive protection. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum.
(5) Circuit Breaker - inverse time breaker. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum.
(6) Recommended Motor circuit protector - Instantaneous trip circuit breaker. The trip setting should be set to the input current of the drive and should be sized for the continuous current of the system.
(7) These DC line fuses (with blown fuse indicators) are included in the drive to provide drive short circuit protection.
480 Volt AC and 650 Volt DC Input Protection Devices - Frames 8…12 (continued)
480 Volt AC Input 650 Volt DC Input
Applied
Rating
(1)
Frame
Cont.
Output
Amps
Duty
Catalog
Number
Output
Overload Amps
Continuous
AC Input
AC Input Integral
Semiconductor Fuse
Size
(170M Type)
(2)
AC Input Protection Devices
Input
Quantities
DC Input
Integral
Semiconductor
Fuse Kit
(7)
Dual Element Time
Delay Fuse
Non-Time Delay Fuse Circuit Breaker
(5)
Motor Circuit
Protector
(6)
Continuous
DC Input
(x = G or J) 1 min 3 sec Amps 2xLCL
Amps
2xLCL
Amps
1xLCL
Amps
1/Phase
Min
(3)
Max
(4)
1/Phase
Min
(3)
Max
(4)
Min Max Amps Amps Qty.