Do you have a question about the Allen-Bradley PowerFlex 755TL and is the answer not in the manual?
Input Voltage | 380-480 V AC |
---|---|
Output Voltage | 0-480 V AC |
Output Frequency | 0-400 Hz |
Input Frequency | 47-63 Hz |
Control Method | V/Hz, Vector |
Communication Protocols | EtherNet/IP, DeviceNet, ControlNet, PROFIBUS |
Enclosure Type | IP20 |
Storage Temperature | -40 to 70 °C |
Relative Humidity | 5-95% non-condensing |
Altitude | Up to 1000 m |
STO | Safe Torque-Off standard |
Provides critical safety warnings and precautions related to handling and operating the interface.
Explains multiple methods for setting the IP address, including rotary switches, parameters, BOOTP, and DHCP.
Provides step-by-step instructions for physically connecting the EtherNet/IP interface to the network.
Guides on setting and verifying critical drive parameters for network command and reference.
Explains how to configure IP address, subnet mask, and gateway using interface parameters.
Details the process of using BOOTP or DHCP servers for automatic IP address assignment.
Explains how to configure the drive's response to communication disruptions or controller state changes.
Describes how to start and configure RSLinx Classic software for network communication.
Details the steps to add the ControlLogix controller's bridge to the I/O configuration in Studio 5000.
Explains how to add the PowerFlex drive as a child device to the Ethernet bridge in the project.
Describes how to select I/O and configure datalinks for communication between controller and drive.
Explains how to use Ethernet switches with DHCP/BOOTP for IP address assignment.
Details the ADC feature for automatic download of drive configuration data by the Logix controller.
Describes datalinks as a mechanism for transferring drive parameter data to/from the controller without explicit messages.
Details the five basic events in the Explicit Messaging process for configuring and monitoring devices.
Provides an example of ladder logic to read a single parameter value from the drive using Get Attribute Single.
Guides on configuring the dialog boxes for a message to read a single parameter.
Provides an example of ladder logic to write a single parameter value to the drive using Set Attribute Single.
Guides on configuring the dialog boxes for a message to write a single parameter.
Provides an example of ladder logic to read multiple parameters using a Scattered Read message.
Guides on configuring dialog boxes for a message to read multiple parameters.
Provides an example of ladder logic to write multiple parameters using a Scattered Write message.
Guides on configuring dialog boxes for a message to write multiple parameters.
Describes how to view interface diagnostic items using drive configuration tools for troubleshooting.