Troubleshooting
8. Compartment 2 of Supply Dispenser Not Flushing Completely
Compartment 2 of the
supply dispenser is not
flushing completely.
Is there low
water pressure
(i.e., less than 30
psi) to the supply
dispenser?
Install a hose clamp onto one of the hoses connecting to the
top of the vacuum breaker and tighten the hose clamp slightly.
Refer to the Vacuum Breaker Illustration.
NOTE: If the water pressure is corrected to factory
specifications, the hose clamp may have to be removed.
As an alternative, cut a 3/4-inch by 1/2 inch notch out of the
bottom of the water deflector in compartment 2 of the supply
dispenser. Refer to the Dispenser Illustration.
NOTE: If the water pressure is corrected to factory
specifications, the notch must be plugged to avoid
splashing.
Ye s
CHM443S
CHM443
S
CHM366S
CHM441S
Notch
Dispenser Illustration Vacuum Breaker Illustration