Hot Water Temperature (Heater/Temp
Sensor only) FL Hot
This option allows the owner to set the hot water temperature
which can be used to set fill temperature in cycle programming.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until FL
Hot appears in the display.
4.
When FL Hot appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Warm Water Temperature (Heater/Temp
Sensor only) FL HC
This option allows the owner to set the warm water temperature
which can be used to set fill temperature in cycle programming.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until FL
HC appears in the display.
4.
When FL HC appears in the display, press the START (enter)
keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Cold Water Temperature (Heater/Temp
Sensor only) FL CLd
This option allows the owner to set the cold water temperature
which can be used to set fill temperature in cycle programming.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until FL
CLd appears in the display.
4.
When FL CLd appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Cool Down Temperature (Heater/Temp
Sensor only) CooLdn
This option allows the owner to set the cool down global water
temperature for cool down steps.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad until Prog appears in the display. Press the START
(enter) keypad, and AtS 1 will appear in the display.
3. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to scroll through the programmable options until
CooLdn appears in the display.
4.
When CooLdn appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (∧) or the DELICATES COLD (∨)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Low Water Level FL Lo
This option allows the owner to set the low water level which can
be used in fill steps to set water levels in cycle programming.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
Programming Control
©