3. Inserting the FPC cable:
At a horizontal angle of
90° to the connector’s
rear (see Figure 3) and
at a vertical angle of 12°
to the PCB (see Figure
4), slowly insert the FPC
cable into the actuator...
Figure 3: FPC cable and FPC connector
4. ...until cable guiding
tabs are caught between
connector rear and side
guides (see Figure 3).
Pull the cable slightly to
ensure guiding tabs are
properly engaged.
5. Holding the FPC cable in
position, flap down the
actuator to closed
position (see Figure 4).
Figure 4: Engaging the FPC cable in the FPC connector
Conductors
Actuator
Connector rear
Side guide
Guiding tab
FPC
connector
FPC cable
90°
90°
FPC cable
Actuator
PCB