AllwiringharnessesandconnectorswhichmatetoAllison
connectors/componentsaretypicallysuppliedandinstalledbythevehicle
manufacturer.Harnessesmayconsistofasinglepiece,ormaybedivided
intomultiplesegmentsjoinedbybulkheadconnectors.
9.2VEHICLEINTERFACEMODULE(VIM)
TheVIMcontainsrelaysandfusesnecessarytointerfacethetransmission
controlswiththevehiclewiringsystem.WhenorderingtheVIM,specify12or
24voltstoproperlymatchthevehicleelectricalsystem.
Insomecases,theOEMorbodybuildermaychoosenottousetheAllison
VIM.Inthesecases,theOEMmustspecifyandinstallcomponentswhich
provideaproperinterfacebetweenvehiclewiringandthetransmission
controlsystem.
9.3RETARDERCONTROLS
Inordertomeettheneedsofoperatorsinawidevarietyofapplications,
vocations,andvehiclecongurations,severalretarderapplysystemsare
offeredfortransmissionmodelsintheAllisonTransmission3000and4000
Series.
Certaintypesofapplysystemsmaynotberecommendedforspecic
vocations.Forexample,factorssuchasretarderperformancethatmaynotbe
appropriatefortheclassorvehicletypeordifcultyininstallation.However,
therearetypicallytwoormoreapplytypesavailableformostvehicles.
Inadditiontothestandardanalogcontrolsapproach,thepossibleintegration
oftheretarderwithnumerousothervehiclesystemsthroughacommonSAE
J1939-basedvehiclecontrollercreatesadditionaldesignexibilitywhen
determiningmethodsofpotentialoperatorcontrolofthetransmissionretarder.
TheTransmissionControlModule(TCM)mustbecalibratedtotheproper
methodtoensuredesiredretarderoperation.Operatorcontrolsoftheretarder
canbeaccomplishedbyeitherofthefollowingmethods:
BothAnalogandJ1939.InputisbasedonaRetarderEnableswitch
foractivation,plusoneormoreAllisonRetarderModulationRequest
(RMR)componentstoselectthedesiredlevelofretardation.Inaddition,
retardationisrequestedorlimitedbasedonmessagesfromanSAE
J1939-basedvehiclecontroller.
J1939Only.Retardationisrequestedorlimitedbasedonmessages
fromanSAEJ1939-basedvehiclecontroller.
Theanalogcomponentsthatcanbeusedwiththe3000and4000Series
retarderareavailablefromAllisonTransmission.Thesecomponentsprovide
145

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allison Transmission 3200 and is the answer not in the manual?

Allison Transmission 3200 Specifications

General IconGeneral
Number of speeds6
RetarderOptional
TypeAutomatic
CompatibilityDiesel
Input Voltage12V or 24V
Communication ProtocolJ1939
Operating Temperature-40°C to 85°C

Related product manuals