8.3 WIND radio sensor
In case of wind alarm the control unit carries out a complete closure and remains on close state for a time
of 12 minutes after the receipt of the last alarm.
During the state of alarm it is possible to carry out the radio learning and the test of the sensor but it is not
possible to carry out any type of handling until the control unit does not exit from the alarm state. The
control unit signals the state of alarm with two beep at the receipt of a control from a user.
8.4 Alarm disconnection radio sensor
In case in which the radio communication between the sensor and the control unit is missing for more than 4
minutes, the control unit closes completely the awning/shutter and remains on state of alarm for
disconnection until the reconnection of the sensor.
During the state of alarm it is possible to carry out the radio learning and the test of the sensor but it is not
possible to carry out any type of operation until the control unit does not exit from the state of alarm.
The control unit signals the state of alarm at the receipt of a control by user.
It is possible to exit from the state of alarm disconnection carrying out a test transmission with radio sensor.
Press the learning key.
1
2
3
The control unit emits three beep.
Press the testing key present on the
radio sensor.
4
The control unit emits one long beep.
The control unit emits four beep.
The learning has had a successful ending.
The control unit is ready to regularly work.
8.5 Radio sensor learning
This procedure allows to learn a radio sensor. The control unit allows to learn one single radio sensor. The
memorization of a second sensor automatically erases the first one memorized.
To erase a memorized radio sensor it is sufficient to repeat the above described operations. The control
unit confirms the happened deletion with two long beep followed by four short beep.
Release the testing key present on
the radio sensor.
WARNING : IT IS NOT POSSIBLE TO DEACTIVATE THE
FUNCTIONALITIES OF THE WIND SENSOR.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allmatic MICRO CAP SENS and is the answer not in the manual?

Allmatic MICRO CAP SENS Specifications

General IconGeneral
BrandAllmatic
ModelMICRO CAP SENS
CategoryControl Unit
LanguageEnglish

Related product manuals