What to do if Allsheng Auto-Pure 32A (T1, T2, T3, T4) overheats?
- SSusan GoldenSep 12, 2025
If your Allsheng Laboratory Equipment (T1, T2, T3, T4) is overheating, the suggested solution is E011, E021, E031, E041.
What to do if Allsheng Auto-Pure 32A (T1, T2, T3, T4) overheats?
If your Allsheng Laboratory Equipment (T1, T2, T3, T4) is overheating, the suggested solution is E011, E021, E031, E041.
What to do if Allsheng Auto-Pure 32A has an open circuit (T1, T2, T3, T4, T5, T6, T7, T8)?
If your Allsheng Laboratory Equipment has an open circuit (T1, T2, T3, T4, T5, T6, T7, T8), the suggested solution is E015, E025, E035, E045, E055, E065, E075, E085.
What to do if Allsheng Laboratory Equipment has a short circuit (T1, T2, T3, T4, T5, T6, T7, T8)?
If your Allsheng Laboratory Equipment has a short circuit (T1, T2, T3, T4, T5, T6, T7, T8), the suggested solution is E016, E026, E036, E046, E056, E066, E076, E086.
What to do if the drive circuit of the exhaust fan is faulty in Allsheng Laboratory Equipment?
If the drive circuit of the exhaust fan is faulty in your Allsheng Laboratory Equipment, the suggested solution is E019.
What to do if the drive circuit of the cooling fan is faulty in Allsheng Laboratory Equipment?
If the drive circuit of the cooling fan is faulty in your Allsheng Laboratory Equipment, the suggested solution is E009.
What to do if the electric machinery brake lock fault in Allsheng Auto-Pure 32A?
If there is an electric machinery brake lock fault in your Allsheng Laboratory Equipment, the suggested solution is E108.
What to do for the clock crystal fault in Allsheng Laboratory Equipment?
If there is a clock crystal fault in your Allsheng Laboratory Equipment, the suggested solution is E702.
What to do if the storage chip E2P fault, setting parameter lost in Allsheng Auto-Pure 32A Laboratory Equipment?
If there is a storage chip E2P fault and setting parameters are lost in your Allsheng Laboratory Equipment, the suggested solution is E703.
How to troubleshoot no display on Allsheng Laboratory Equipment after switching on?
If your Allsheng Laboratory Equipment shows no display after being switched on, several factors could be at play. First, ensure that the power is correctly connected. If the power connection is secure, the issue might stem from a switch failure, necessitating a switch replacement. Another potential cause is a blown fuse; in this case, replace the fuse with a ?5X20 250V 8A? fuse.
Why is there a big variance between actual and display temperature in my Allsheng Laboratory Equipment?
If you are experiencing a big variance between actual and display temperature for your Allsheng Laboratory Equipment, this may be due to sensor failure. Contact your distributor.
Emphasizes reading the manual, indoor use, and avoiding unauthorized modifications for safe operation, including warnings on heat and electrical hazards.
Details normal operating environmental conditions, technical specifications, and performance metrics of the Auto-Pure system.
Guides on unpacking, initial preparation, connecting power, and installing the reagent kit for first-time use.
Lists common operational issues, their potential causes, and recommended solutions for the instrument.
Provides a list of software fault types, corresponding error messages, and affected instrument models for troubleshooting.
| Category | Laboratory Equipment |
|---|---|
| Model | Auto-Pure 32A |
| Brand | Allsheng |
| Throughput | 1-32 samples per run |
| Sample Volume | 50-1000 μL |
| Processing Time | 15-60 minutes |
| Heating Temperature | Room temperature to 90°C |
| Power Supply | AC220V, 50/60Hz |