ALORAIR Sentinel HDi90 Specifications

General IconGeneral
ModelSentinel HDi90
CategoryDehumidifier
Capacity90 pints per day
Coverage Area2, 600 sq. ft.
RefrigerantR410A
DrainageGravity Drain or Pump
Airflow210 CFM
Power Supply115V/60Hz
Auto RestartYes
Warranty5 years
Noise Level52 dB
Defrost FunctionAutomatic
FilterWashable
Operating Temperature33°F to 104°F

Summary

Safety Notes

General Safety Precautions

Adheres to grounded electrical connections, qualified technician for maintenance, and proper unit orientation.

Electrical Supply Requirements

Power and Outlet Specifications

Requires 220V, 50 Hz AC, 1 Phase, 3-prong GFI outlet with a 15 Amp time delay fuse or breaker.

Safety Warnings for Electrical Connection

Emphasizes avoiding extension cords, plug adapters, and ensuring grounded circuits to prevent shock.

Principle of Operation

Installation Procedures

Power Connection

Plug the unit into a 15 amp grounded circuit for safe operation.

Key Functions and Controls

Power and Humidity Setting

Use the Power key to turn the unit on/off, and arrow buttons to set desired humidity (36-90%).

Indicator Lights

Operating Instructions

Starting and Adjusting Operation

Turn the machine on using the power key and adjust the desired humidity setpoint using arrow keys.

Maintenance Procedures

Preventative Pump System Cleaning

Clean pump system annually, including drain pan, hose, reservoir, and discharge tubing.

Pump Cleaning and Disinfection

Basic Pump Cleaning Procedure

Clean pump reservoir with bleach or vinegar solution, flush with water, and repeat if necessary.

Advanced Pump Cleaning Procedure

Disassemble pump, clean reservoir, and flush system with bleach/vinegar solution for thorough disinfection.

Troubleshooting Common Issues

Machine Won't Run and Airflow Issues

Check power supply, temperature range, filter, and air blockage for machine not running or low airflow.

Error Codes E1 and E4

Troubleshoot E1 by checking sensor connection; for E4, verify pump operation and reset unit.

Pump Alarm (E2/E4) Resolution

Reset unit, check pump operation, clear discharge line obstruction, and replace parts if needed for pump alarm.