Chapter 1 Purchase Inspection
7
Item Description
put/Output interface
Encoder Input Interface
1 maximum received pulse 300KHZ
cables-driven mannersStandard RS422
communication interface
Pulse Input Inerface
1 roadorientation +pulse/ orthogonal pulse
/CW+CCW
Encoder Output Interface
1 roadfrequency dividing output 11
cables-driven mannersStandard RS422
communication interface
All line interface
1 road485 all line
Spindle funtion
Speed control
Range08000RPM;Rotation Direction
positative and negativeSpeed command
codeunipolarity and bipolarity analog
valuepulse frequencyall line
Precision stop control
Precision:±1Pulse8 position is available
via terminals.
rigidity tapping
Work with a variety of domestic and
imported systemTapping error rate 2%
other
C axis control, thread cutting, electronic
gear, reaming, zero speed lock
Protective
funtion
overload protection Drive and motor overload protection
Overcurrent protection
Overcurrent protection is implemented by
hardware
Under-voltage/over-voltage
protection
Start the protetive function when the voltage
is over than 800V or less than 350V
Output of short circuit protection
Output a alarm signal when the output to
groud is a short circuit.

Table of Contents