INSTANT WATER HEATER
QUICK INSTALLATION GUIDE
(You are still required to refer to the instruction manual before installation)
1
Question and Answer IconNeed help?

Do you have a question about the Alpha MULTIPOINT Series and is the answer not in the manual?

Alpha MULTIPOINT Series Specifications

General IconGeneral
BrandAlpha
ModelMULTIPOINT Series
CategoryWater Heater
LanguageEnglish

Summary

Product Types and Applications

Type 1: Single Point Opened Outlet Heater

Describes the Type 1 single point opened outlet heater.

Type 2: Single Point Heater with Built-in Pump

Describes the Type 2 heater with a built-in pump for low water pressure.

Type 3: Multipoint Installation System

Explains multipoint installation serving multiple outlets.

Critical Safety Precautions

Installation and Usage Restrictions

Avoid reverse installation, direct spray, and unauthorized repairs.

Operational Safety Checks

Check AUTO TEST indicator, ensure no outlet blockage, and test water temperature.

Supervision and Professional Installation

Do not leave unsupervised persons in shower; engage qualified electrician.

Installation Tools and Equipment

Essential Hand and Power Tools

Lists necessary tools like screwdrivers, spanners, pliers, drills, and wire cutters.

Safety Gear and Testing Equipment

Includes safety shoes, water pump pliers, and test pens for installation.

Electrical Requirements: Direct Wiring

Wire Cable Size Guidelines

Details wire cable size requirements based on heater wattage (kW) for direct wiring.

Electrical Safety: Plug Restrictions

Prohibited Plug Types

Prohibits the use of 13A and 15A 3-pin plugs for the heater connection.

Electrical Safety: Circuit Breakers

MCB Rating Recommendations

Specifies the appropriate MCB amperage rating for different heater power outputs.

Heater Component Overview

Controls, Indicators, and Water Valves

Identifies knobs, buttons, indicators, stop valve, filter, and regulator units.

Shower Head and Rail System Parts

Lists components like handshower, flexible hose, shower holder, and sliding rail supports.

Rain Shower Assembly Guide

Sliding Rail and Handshower Setup

Illustrates the arrangement and connection of rain shower head, sliding rail, and handshower.

Installation Procedure Steps

Initial Setup: Power and Water Isolation

Confirming Electrical and Water Shut-off

Steps to turn off MCB, heater switch, check for zero current, and shut off water supply.

Determining Optimal Installation Heights

Rain Shower and Heater Unit Placement

Recommended installation heights for rain shower (2m) and heater unit (1.5m or eye level).

Heater Mounting and Water Connections

Securing the Heater and Initial Water Flow

Steps for mounting the heater unit and connecting water supply to clear dirt and fill tank.

Electrical Wiring and Final Assembly

Cable Entry, Wiring, and Cover Installation

Options for cable entry, correct wiring, and final cover fastening.

Installation Tip: Wire Entry Protection

Proper Use of Rubber Grommet

Importance of using the rubber grommet for side wire entry to prevent insect and water damage.

Post-Installation Test Run

Verifying Heater and Water Flow Operation

Steps to confirm proper operation after installation, including water flow and heating.

ELSD Safety Feature Check

Testing the Earth Leakage Sensing Device

Procedure to test ELSD function via TEST and RESET buttons for safety assurance.

Built-in Pump Operation Guide

Controlling Pump Speed and Activation

How to adjust pump speed and activate it manually for weak water pressure.

Shower Accessories Installation

Mounting Shower Holder and Rail Supports

Instructions for fixing shower holder and rail supports onto the sliding rail assembly.

Rain Shower Installation: Step 1 & 2

Drilling Holes and Securing Fix Plates

Steps for drilling holes according to dimensions and securing fix plates for mounting.

Rain Shower Installation: Step 3-5

Sliding Rail Assembly and Shower Head Attachment

Joining sliding rail sections and connecting the rain shower head to the assembly.

Rain Shower Installation: Step 6-8

Hose Connections and Spray Pattern Selection

Connecting flexible hoses and choosing desired water spray patterns from the shower head.

Multipoint Hot Water System Installation

System Configuration and Usage Limitations

Details for 6.0kW/8.0kW systems and notes on limiting simultaneous outlet usage.

Multipoint System Test Run

Inlet/Outlet ID, Valve Install, and Initial Tap Use

Identifying inlet/outlet, installing pressure relief valve, and initial tap operation before heater activation.

Auto Test Functionality Explained

Interpreting M5/Smart 18 Series Auto Test Lights

Understanding GREEN for safe mode and RED blinking for ELCB faults in M5/Smart 18 models.

Auto Test Indicator Guide for SMART 18

Decoding SMART 18 Auto Test Light Signals

Explains GREEN indicator for safe ELCB and RED for fault conditions in SMART 18 series.

Common Single Point Heater Installation Errors

Incorrect Inlet/Outlet and Stop Valve Placement

Avoiding reverse connections, incorrect stop valve installation, and checking labels.

General Guidance for Operation and Adjustment

Water Connections and Control Adjustments

Connecting water inlets/outlets and adjusting regulator for water volume/temperature.

Maintenance: Stop Valve Cleaning

Step-by-Step Stop Valve Maintenance

Visual guide on how to disassemble, clean, and reassemble the stop valve for optimal function.

Maintenance: Hand Shower Filter Cleaning

Cleaning the Hand Shower Filter Mesh

Instructions on how to remove and clean the filter mesh located in the hand shower head.

Maintenance: Pressure Relief Valve Check

Pressure Relief Valve Cleaning and Verification

Guide for multipoint models to clean or replace the pressure relief valve if blocked.

Troubleshooting: No Shower or ELCB Issues

Diagnosing No Water Flow or ELCB Tripping

Addresses causes like blocked filters, low water supply, or ELCB faults and their remedies.

Troubleshooting: Temperature and Flow Problems

Addressing Insufficient Heating or Overheating

Solutions for showers not hot enough or outlet water being too hot, including flow and voltage issues.