22 4175654-Ed.01 (2013/01)
4.2 Electrical connection
DANGER:
Work on the electrical connection may only
be performed by a qualified electrician in accordance
with national and local regulations.
Before establishing the connection, make sure that the
connecting cable is dead.
Mains voltage and current type have to correspond to the
rating plate specifications.
Connect the plug (Fig. 4a to 4e).
Mains connection: L, N, PE.
Max. back-up fuse:10 A, slow.
Earth the pump according to the regulations.
Dismantle the plug in accordance with Fig. 5. A screwdriver
is needed for this.
The electrical connection is to be established via a fixed
connection line equipped with a connector device or an all-
pole switch with a contact opening width of at least 3 mm.
To ensure drip protection and strain relief at the PG
screwed connection, a connected load with an adequate
outer diameter is necessary (e.g. H05VV-F3G1.5 or
AVMH-3x1.5).
When pumps are used in systems with water temperatures
above 90°C, a suitably heat-resistant connected load is
installed.
The connected load is to be placed in such a way that it can
under no circumstances come into contact with the pipe
and/or the pump and motor housing.
The switching of the pump via triacs/solid-state relays is to
be checked on an individual basis.