#8405 QUICKCHILLER INSTALLATION, OPERATION, AND MAINTENANCE
Pg. 7.
®
ELECTRICAL INSTALLATION
VOLTAGE PHASE CYCLE/HZ
Q C - 3 Q C - 2 0 Q C - 4 0 Q C - 5 0 Q C - 1 0 0
S E L F - C O N TA I N E D
208-240VAC 1 ph 50/60 Hz
Recommended
circuit amperage:
20 amps
Recommended
circuit amperage:
20 amps
Recommended
circuit amperage:
30 amps
Recommended
circuit amperage:
40 amps
Recommended
circuit amperage:
60 amps
Recommended
wire size:
12/2 w.g.
Recommended
wire size:
12/2 w.g.
Recommended
wire size:
8/2 w.g.
Recommended
wire size:
8/2 w.g.
Recommended
wire size:
6/2 w.g.
N
O C O R D A N D P L U G
VOLTAGE PHASE CYCLE/HZ
Q C - 3 Q C - 2 0 Q C - 4 0 Q C - 5 0 Q C - 1 0 0
S E L F - C O N TA I N E D
208-240VAC 3 ph 50/60 Hz
NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE
Recommended
circuit amperage:
20 amps
Recommended
circuit amperage:
40 amps
Recommended
wire size:
12/3 w.g.
Recommended
wire size:
8/3 w.g.
N O C O R D A N D P L U G
VOLTAGE PHASE CYCLE/HZ
Q C - 3 Q C - 2 0 Q C - 4 0 Q C - 5 0 Q C - 1 0 0
R E M O T E C O M P R E S S O R
208-240VAC 1 ph 50/60 Hz
(Cabinet Only)
NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE
Recommended
circuit amperage:
20 amps
Recommended
circuit amperage:
30 amps
Recommended
wire size:
12/2 w.g.
Recommended
wire size:
10/2 w.g.
N O C O R D A N D P L U G

Other manuals for Alto-Shaam Quickchiller QC-20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam Quickchiller QC-20 and is the answer not in the manual?

Alto-Shaam Quickchiller QC-20 Specifications

General IconGeneral
BrandAlto-Shaam
ModelQuickchiller QC-20
CategoryChiller
LanguageEnglish

Related product manuals