#8405 — QUICKCHILLER INSTALLATION, OPERATION, AND MAINTENANCE
Pg. 6.
This appliance must be branch circuit protected
with proper ampacities, in accordance with the
wiring diagram. The Quickchiller must be
properly grounded in accordance with the
National Electrical Code and applicable local
codes. Wire size for the main incoming power to
the unit must match the minimum size listed in
the specifications applicable to the specific
Quickchiller model. For supply connections,
locate the wire size listed in this manual.
Before operating the chiller, check all cable
connections in the electrical connection area
for tightness since connections can loosen
during transport.
N O T E : After electrical connections have been
completed, operate the appliance in
any chilling mode for a period of 15
minutes and recheck the main power
connections at the terminal block to
make certain they remain tight.
ELECTRICAL INSTALLATION