TROUBLESHOOTING
Vector H Seri es Serv ic e M anua l MN- 4654 4 Re v 01 1 1/19
68
Continued from previous page
10. Measure the amp draw while the heater is on. The amperage draw of a
functioning heater element is 10-15 amps.
11. Touch the heater button k to stop the heater. The heater and convection
fan buttons will turn white.
12. Cool the oven.
13. Re-install the side panel.
Result The heaters have now been tested.
WARNING: Electric shock hazard. Wear PPE and use
best practices when measuring live voltage.