EasyManua.ls Logo

Alto-Shaam Vector VMC-H3 - Page 33

Alto-Shaam Vector VMC-H3
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
Vecto r H® S eries Operat ors M anual M N-46 2 95 Rev 7 6/22
33
Continued from previous page
Voltages
Continued on next page
V Ph Hz A Breaker* kW
Wire
Size
(mm)
VMC-H2H
220–240V
380–415V
220
240
380
415
1
1
3
3
50
50
50
50
25
28
12
13
32
32
16
16
5.4
6.4
5.4
6.4
4
4
1.5
1.5
VMC-H3H
220–240V
380–415V
220
240
380
415
1
1
3
3
50
50
50
50
37
41
12
13
63
63
16
16
8.1
9.6
8.1
9.6
10
10
1.5
1.5
VMC-H4H
380–415V
380
415
3
3
50
50
23
25
32
32
10.8
12.7
4
4
VMC-H2HW
200–240V
200–240V
220–240V
380–415V
200
240
200
240
220
240
380
415
1
1
3
3
1
1
3
3
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
32
38
18
22
35
38
20
22
50
50
40
40
63
63
32
32
6.5
9.1
6.5
9.1
7.7
9.1
7.7
9.1
8
8
10
10
10
10
4
4
VMC-H3HW
200–240V
380–415V
200
240
380
415
3
3
3
3
50/60
50/60
50/60
50/60
28
33
30
33
50
50
63
63
9.7
13.6
11.5
13.6
8
8
6
6
*Electrical connections must meet all applicable federal, state, and local codes.