Primary data Unit General Nominal values Tolerances
Voltage VAC 230 +6/-10%
Frequency Hz 50
Motor coupling 3
Number of phases Pce. 1
Power consumption A 12 +-1.5
High voltage KV 2.4 in 2 sec.
Leakage current mA 0.75
Resistance in ground circuit Ohm 0.2
Absorption power kW 2.9
Axel power kW 2.1
Revolutions Min-1 1430 1420-1470
Control voltage VAC 230 +-10%
Signal voltage microprocessor VAC 5 +-10%
IP classification 45
Bypass time auto start/stop Sec 20
Bypass time manual Min 5
Water volume, high-pressure l/min 11.5
Water volume, low-pressure l/min 12.5
Machine's pressure gauge Bar 105 +-8.5%
Pump pressure, high-pressure Bar 101
Pressure, h-p pump outlet Bar 93
Opening pressure, pump outlet Bar 125 +-7
Bypass pressure Bar 10.5 +-4
Suction capacity Bar 0.17
Suction height, primed m 3
Max. water inlet temperature °C85
Max. water inlet pressure Bar 10
Reaction force, max. N 54
Acoustic pressure level dBA 75.4
Oil volume Litre 0.5
Oil type Pump oil 100