12
ADR=3 VP=4
Now you must choose which weather variable to reference your
prediction against. The standard is to use DA or OA (if the unit is
oxygen sensor equipped), but you can select ADR or VP if you wish.
One Run:
When One Run prediction method is selected you must set your base run
and performance ratios.
Set Base Run=1
Set Pred Value=2
View Values=3
Done =ENTER
Set Base Run:
Your base run data should be taken from a “good run” or your last “good
run”. You can update this data as you wish.
Enter Base Run
DA=
ET=
Timer= (if in TS mode)
Temperature= (if fuel type=Alcohol)
Humidity= (if fuel type=Alcohol)
Set Pred Values:
Set Pred Values allows you to select your gas type and your DA to ET
and TS to ET ratios.
Select
Gas=1 Alcohol=2
Now you will be prompted to choose between preset ratios or allowed to
enter custom ratios.
Preset Ratios=1
Custom Ratios=2
Custom Ratios:
Enter DA Ratio
Enter how many foot of Altitude it takes to move you vehicle 0.01sec in
ET. (Ex: 150 means it takes 150’DA to make ET change 0.01sec)