10 Dishwasher / User’s Manual/41 EN
Installation
Permitted water temperature: 
up to 25°C ( 60°C for products 
equipped with Aquasafe+; please 
refer toAquasafe+ section )
The dishwasher may not be connected to 
open warm water devices or flow-through 
water heaters.
The dishwasher should be connected to 
cold water inlet.
 • Do not use old or used water inlet 
hose on the new product. Use the new 
water inlet hose supplied with the 
product.
 • Connect the water inlet hose directly 
to the water tap. Pressure coming 
from the tap should be minimum 0.3 
and maximum 10 bars. If the water 
pressure exceeds 10 bars, a pressure 
relief valve should be installed in 
between.
 • Open the taps completely after making 
the connections to check for water 
leaks.
C
Use a screw-on hose connector 
to connect the water inlet hose 
to a water tap with a ¾ inch 
external thread. If required, use 
a filter insert to filter deposits 
from the pipes.
A
For your safety, close the water 
inlet tap completely after the 
washing programme is over.
Connecton to the dran
Water discharge hose can directly be 
connected to the drain hole or sink’s 
drainage. The length of this connection 
must be min. 50 cm and max. 100 cm from 
the floor. A discharge hose longer than 4 
meters causes dirty washing.
Attach the water discharge hose to the 
drainpipe without bending it. Tightly fix 
the water discharge hose to the drainpipe 
in order to prevent any dislocation of the 
water discharge hose during operation of 
the product. 
min
300
min
120
max 1000
min 500
C
Drainpipe must be connected 
to the sewage system and it 
should not be connected to any 
surface water.
Adjustng the feet
If the door of the product cannot be closed 
properly or if the product swings when you 
push it slightly, then you need to adjust