Specifi cation Sheet
SS-ASH13 www.amana-hac.com 7
PERFORMANCE RATINGS (CONT.)
Heat
Pump
Coil / Air Handler
Total
BTU/h
Sensible
BTU/h
SEER EER
Heating Capacity
dBs
47° F
(Btuh)
47°F
(COP)
HSPF
17°F
(Btuh)
17°F
(COP)
ASH130481A* (cont.)
CHPF060D2* / CHPF4860D6A*+EEP 45,000 34,000 13.0 12 43,000 3.50 8.2 27,000 2.40
76
CHPF060D2* 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CHPF4860D6A* + A*V80905C** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CHPF060D2* 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CHPF4860D6A* + A*V81155C** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CHPF060D2* 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CHPF4860D6A* + A*V90905D** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CHPF060D2* 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CHPF4860D6A* + A*V91155D** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
H61F / CSCF4860N6A* + EEP 45,000 34,000 13.0 12 43,000 3.50 8.2 27,000 2.40
H61F / CSCF4860N6A* + A*V80905C** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
H61F / CSCF4860N6A* + A*V81155C** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
H61F / CSCF4860N6A* + A*V90905D** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
H61F / CSCF4860N6A* + A*V91155D** 45,000 34,000 13.5 12 43,000 3.50 8.3 27,000 2.40
CA*F061*2* / CA*F4860 *6A* + MBE2000 45,000 34,000 14.0 12 43,000 3.60 8.4 27,000 2.50
ASH130601A*
AEPT060-00*-1* / AEPF42601A* 55,500 40,000 13.3 12 55,500 3.60 8.6 35,000 2.60
77
ARPF060-00B-1* / ADPF48601A* 55,500 40,000 13.0 12 55,500 3.50 8.5 35,000 2.50
ARPT061-00*-1* / ARPF48601A* 55,500 40,000 13.0 12 55,500 3.50 8.5 35,000 2.50
ARUF061-00*-1* / ARUF48601A* 55,500 40,000 13.0 12 55,500 3.50 8.5 35,000 2.50
CA*F061*2* / CA*F4860 *6A* + EEP 55,500 40,000 13.0 12 55,500 3.50 8.5 35,000 2.50
CA*F061*2* / CA*F4860*6* + A*V80905C** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CA*F061*2* / CA*F4860*6* + A*V81155C** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CA*F061*2* / CA*F4860*6* + A*V9115D** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CHPF060D2* / CHPF4860D6A* + EEP 55,500 40,000 13.0 12 55,500 3.50 8.5 35,000 2.50
CHPF060D2* 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CHPF4860D6A* + A*V80905C** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CHPF060D2* 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CHPF4860D6A* + A*V81155C** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CHPF060D2* 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
CHPF4860D6A*+ A*V9115D** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
H61F / CSCF4860N6A* + EEP 55,500 40,000 13.0 12 55,500 3.50 8.5 35,000 2.50
H61F / CSCF4860N6A* + A*V8090C** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
H61F / CSCF4860N6A* + A*V81155C** 55,500 40,000 13.3 12 55,500 3.50 8.5 35,000 2.50
H61F / CSCF4860N6A* + A*V91155D** 55,500 40,000 13.2 12 55,500 3.50 8.5 35,000 2.50
CA*F061*2* / CA*F4860 *6A* + MBE2000 55,500 40,000 13.5 12 55,500 3.60 8.6 35,000 2.60
NOTES:
1) Certified per ARI 210/240 @ 80 °F/67 °F/95 °F
2) Seasonal Energy Efficiency Ratio
3) Energy Efficiency Ratio @ 80 °F/67 °F/95 °F
4) HSPF = Heating Seasonal Performance Factor
5) Order the EEP from the Service Department using Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not
interchangeable with B13707-35S.
When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size.