CONDENSING UNIT


is a registered trademark of Maytag Corporation or its related
companies and is used under license. All rights reserved.
© 2021-2022
Daikin Comfort Technologies Manufacturing, L.P.


 

The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards.
It is the owner’s and installer’s responsibility to read
and comply with all safety information and instructions
accompanying these symbols. Failure to heed safety
information increases the risk of personal injury, property
damage, and/or product damage.









THIS MANUAL SHOULD




















SHIPPING INSPECTION
Always keep the unit upright; laying the unit on its side
or top may cause equipment damage. Shipping damage,
and subsequent investigation is the responsibility of
the carrier. Verify the model number, specications,
electrical characteristics, and accessories are correct
prior to installation. The distributor or manufacturer will not
accept claims from dealers for transportation damage or
installation of incorrectly shipped units.

This product is designed and manufactured to comply
with national codes. Installation in accordance with such
codes and/or prevailing local codes/regulations is the
responsibility of the installer. The manufacturer assumes
no responsibility for equipment installed in violation of any
codes or regulations. Rated performance is achieved after
20 hours of operation.
Rated performance is delivered at the specied airow.
See outdoor unit specication sheet for split system models
or product specication sheet for packaged and light
commercial models. Specication sheets can be found at
www.goodmanmfg.com for Goodman® brand products or
www.amana-hac.com for Amana® brand products. Within
either website, please select the residential or commercial
products menu and then select the submenu for the type
of product to be installed, such as air conditioners or heat
pumps, to access a list of product pages that each contain
links to that model’s specication sheet.





Should you have any questions please contact the local
o󰀩ce of the EPA.
If replacing a condensing unit or air handler, the system
must be manufacturer approved and Air Conditioning,
Heating and Refrigeration Institute (AHRI) matched.


Question and Answer IconNeed help?

Do you have a question about the Amana ASXN3 Series and is the answer not in the manual?

Amana ASXN3 Series Specifications

General IconGeneral
RefrigerantR-410A
StagesSingle-Stage
TypeHeat Pump
SEER RatingUp to 16 SEER
HSPF RatingUp to 9.0 HSPF
Compressor TypeSingle-Stage
Warranty10-year limited warranty on compressor and parts
Cooling Capacity (BTU/h)18, 000-60, 000 BTU/h
Heating Capacity (BTU/h)18, 000-60, 000 BTU/h

Summary

IMPORTANT SAFETY INSTRUCTIONS

GENERAL SAFETY WARNINGS

Covers high voltage, personnel qualifications, and safety devices.

INSTALLATION CLEARANCES AND FOUNDATION

AIRFLOW CLEARANCES AND FOUNDATION REQUIREMENTS

Specifies minimum clearances and foundation needs for unit placement.

SAFE REFRIGERANT HANDLING

REFRIGERANT HAZARDS AND PRECAUTIONS

Covers asphyxiation, cold burns, and legal reclamation of refrigerants.

REFRIGERANT LINES AND CONNECTIONS

REFRIGERANT LINE BRAZING AND TESTING

SYSTEM EVACUATION AND ELECTRICAL CONNECTIONS

EVACUATION METHODS AND WARNINGS

Covers safe evacuation and compressor precautions.

ELECTRICAL CONNECTION SAFETY

High voltage hazards and proper wiring practices.

SYSTEM START-UP AND COMPRESSOR ROTATION

CHARGE VERIFICATION AND FIXED ORIFICE SYSTEMS

REFRIGERANT CHARGE VERIFICATION

Warnings, cautions, and steps for verifying system charge.

EXPANSION VALVE SYSTEM CHARGING

TROUBLESHOOTING INFORMATION

COMPLAINT ANALYSIS AND REMEDIES

Guide linking complaints to causes, symptoms, test methods, and fixes.

SPLIT SYSTEMS ROUTINE MAINTENANCE

START-UP CHECKLIST