EasyManua.ls Logo

Amana ASXH5 Series User Manual

Amana ASXH5 Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
CONDENSING UNIT


is a registered trademark of Maytag Corporation or its related
companies and is used under license. All rights reserved.
© 2021-2022
Daikin Comfort Technologies Manufacturing, L.P.


 

The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards.
It is the owner’s and installer’s responsibility to read
and comply with all safety information and instructions
accompanying these symbols. Failure to heed safety
information increases the risk of personal injury, property
damage, and/or product damage.









THIS MANUAL SHOULD




















SHIPPING INSPECTION
Always keep the unit upright; laying the unit on its side
or top may cause equipment damage. Shipping damage,
and subsequent investigation is the responsibility of
the carrier. Verify the model number, specications,
electrical characteristics, and accessories are correct
prior to installation. The distributor or manufacturer will not
accept claims from dealers for transportation damage or
installation of incorrectly shipped units.

This product is designed and manufactured to comply
with national codes. Installation in accordance with such
codes and/or prevailing local codes/regulations is the
responsibility of the installer. The manufacturer assumes
no responsibility for equipment installed in violation of any
codes or regulations. Rated performance is achieved after
20 hours of operation.
Rated performance is delivered at the specied airow.
See outdoor unit specication sheet for split system models
or product specication sheet for packaged and light
commercial models. Specication sheets can be found at
www.goodmanmfg.com for Goodman® brand products or
www.amana-hac.com for Amana® brand products. Within
either website, please select the residential or commercial
products menu and then select the submenu for the type
of product to be installed, such as air conditioners or heat
pumps, to access a list of product pages that each contain
links to that model’s specication sheet.





Should you have any questions please contact the local
o󰀩ce of the EPA.
If replacing a condensing unit or air handler, the system
must be manufacturer approved and Air Conditioning,
Heating and Refrigeration Institute (AHRI) matched.


Question and Answer IconNeed help?

Do you have a question about the Amana ASXH5 Series and is the answer not in the manual?

Amana ASXH5 Series Specifications

General IconGeneral
BrandAmana
ModelASXH5 Series
CategoryHeat Pump
LanguageEnglish

Summary

Important Safety Instructions

High Voltage Safety Warning

Warning about disconnecting all power before servicing...

Service by Qualified Personnel

Only trained personnel should service the equipment...

Avoid Bypassing Safety Devices

Warning regarding the bypass of safety devices...

Safe Refrigerant Handling

General Refrigerant Safety

Essential safety guidelines for handling refrigerants to avoid injury and ensure proper ventilation.

Refrigerant Cylinder Safety

Safety warnings related to handling refrigerant cylinders, including heating and filling.

Refrigerant Line Connections and Pressure Testing

System Evacuation and Electrical Connections

System Evacuation Methods

Steps for evacuating the system using the Deep Vacuum Method to remove air and moisture.

Charge Verification and Adjustment

Refrigerant Charge Verification

Methods and guidelines for verifying the refrigerant charge using superheat and subcooling.

Final Charge Adjustment Procedure

Procedure for adjusting the refrigerant charge to achieve proper superheat and subcooling settings.

Expansion Valve System and TXV Adjustments

Troubleshooting Common Issues