Model | M9S96 Series |
---|---|
Efficiency | Up to 96% AFUE |
Heating Capacity | 40, 000 to 120, 000 BTU/H |
Stages | Two-Stage |
Fuel Type | Natural Gas or Propane |
Warranty | Limited Lifetime Heat Exchanger, 10-year Parts |
Instructions for suspending the furnace from rafters or joists using threaded rod and angle iron.
Procedure to relocate the pressure switch tube for horizontal installations.
Details on PVC, CPVC, and ABS pipe materials and fittings for venting and intake.
Requirements for vent components in Canada, including ULC S636 standards.
Details on factory installed drain traps and hose routing for various furnace models.
Explanation of color-coded wiring harness and replacement wire specifications.
Instructions for observing line polarity during field connections for electrical wiring.
Specifies minimum and maximum inlet gas pressures for natural and propane gas.
Guidelines for designing ductwork based on furnace CFM and static pressure ratings.
Check furnace cabinet sealing components for proper installation and to prevent air leakage.
Instructions for filling the drain trap with water before furnace startup.
Step-by-step procedure for starting up the furnace safely.
Detailed steps of the furnace's operation sequence during a call for heat.
Procedure for testing gas supply pressure using a manometer.
Steps for measuring and adjusting gas manifold pressure with burners operating.
Table showing airflow (CFM) at various static pressures for low stage cooling.
Table showing airflow (CFM) at various static pressures for high stage cooling.
Table showing airflow (CFM) at various static pressures for circulation fan operation.
Table showing airflow (CFM) and temperature rise at various static pressures for heating.
Table showing airflow (CFM) at various static pressures for low stage cooling.
Table showing airflow (CFM) at various static pressures for high stage cooling.
Table showing airflow (CFM) at various static pressures for circulation fan operation.
Table showing airflow (CFM) and temperature rise at various static pressures for heating.
Table showing airflow (CFM) at various static pressures for low stage cooling.
Table showing airflow (CFM) at various static pressures for high stage cooling.
Requirements for installing hard-wired and battery-operated carbon monoxide detectors.
Specifications for approved carbon monoxide detectors, including NFPA 720 and ANSI/UL 2034.
Requirement for metal or plastic identification plate for gas vent signage.
State or local gas inspector must observe detectors and signage for approval.