IOG-2015E
7/2020
19001 Kermier Rd., Waller, TX 77484
www.goodmanmfg.com•www.amana-hac.com
© 2018-2020 Goodman Manufacturing Company, L.P.
is a registered trademark of Maytag Corporaon or its related companies and is used under license. All rights
reserved.
As a professional installer you have an obligation to know
the product better than the customer. This includes all
safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself
with this Instruction Manual. Pay special attention to all
safety warnings. Often during installation or repair it is
possible to place yourself in a position which is more
hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product
safely and to know it well enough to be able to instruct a
customer in its safe use.
Safety is a matter of common sense...a matter of thinking
before acting. Most dealers have a list of specic good
safety practices...follow them.
The precautions listed in this Installation Manual are
intended as supplemental to existing practices. However,
if there is a direct conict between existing practices and
the content of this manual, the precautions listed herein
take precedence.


*NOTE: Please contact your distributor or our website
for the applicable Specication Sheet referred to in this
manual.



These furnaces comply with requirements embodied
in the American National Standard/National Standard
of Canada ANSI Z21.47•CSA-2.3 Gas Fired Central
Furnaces.
O
NLY
PERSONNEL
THAT
HAVE
BEEN
TRAINED
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
(
HEREINAFTER
, “
SERVICE
”)
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
SHOULD
SERVICE
THE
EQUIPMENT
. T
HE
MANUFACTURER
WILL
NOT
BE
RESPONSIBLE
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
ARISING
FROM
IMPROPER
SERVICE
OR
SERVICE
PROCEDURES
. I
F
YOU
SERVICE
THIS
UNIT
,
YOU
ASSUME
RESPONSIBILITY
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
WHICH
MAY
RESULT
. I
N
ADDITION
,
IN
JURISDICTIONS
THAT
REQUIRE
ONE
OR
MORE
LICENSES
TO
SERVICE
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
ONLY
LICENSED
PERSONNEL
SHOULD
SERVICE
THE
EQUIPMENT
. I
MPROPER
INSTALLATION
,
ADJUSTMENT
,
SERVICING
OR
REPAIR
OF
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
OR
ATTEMPTING
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
WITHOUT
PROPER
TRAINING
MAY
RESULT
IN
PRODUCT
DAMAGE
,
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.



Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
0140M00517-A
Question and Answer IconNeed help?

Do you have a question about the Amana MVC961005CN Series and is the answer not in the manual?

Amana MVC961005CN Series Specifications

General IconGeneral
ModelMVC961005CN
TypeGas Furnace
Efficiency Rating96% AFUE
Blower MotorVariable Speed
Ignition TypeDirect Spark Ignition
Fuel TypeNatural Gas
StagesTwo-Stage
Heat ExchangerStainless Steel
WarrantyLifetime Heat Exchanger Limited Warranty
Vent Diameter2 inch or 3 inch
Filter Size16" x 25"
Heating Capacity100, 000 BTU/h
Cabinet TypeInsulated

Summary

INSTALLATION INSTRUCTIONS FOR *CVC96*BB & *MVC96*BB Two-Stage Gas FURNACE

SAFETY CONSIDERATIONS

LOCATION REQUIREMENTS & CONSIDERATIONS

Guidelines for selecting a suitable installation location for the furnace.

COMBUSTION & VENTILATION AIR REQUIREMENTS

Ensuring adequate airflow for proper combustion and ventilation.

VENT/FLUE PIPE & COMBUSTION AIR PIPE

Requirements for vent and combustion air piping installation.

PRODUCT APPLICATION

LOCATION REQUIREMENTS & CONSIDERATIONS

CLEARANCES AND ACCESSIBILITY

COMBUSTION & VENTILATION AIR REQUIREMENTS

INSTALLATION POSITIONS

DRAIN TRAP AND LINES

VENT PIPE & COMBUSTION AIR

TERMINATION LOCATIONS

VENT/FLUE PIPE TERMINATIONS

VENT/FLUE AND COMBUSTION AIR PIPE TERMINATIONS

SPECIAL INSTRUCTIONS FOR PRODUCTS INSTALLED IN THE STATE OF MASSACHUSETTS

INSTALLATION OF CARBON MONOXIDE DETECTORS

Requirements for CO detector installation.

CONDENSATE DRAIN LINES & DRAIN TRAP

DRAIN EXITING RIGHT SIDE

DRAIN EXITING LEFT SIDE

COUNTERFLOW MODEL INSTALLED VERTICALLY

INLET GAS SUPPLY PRESSURE

GAS SUPPLY AND PIPING

PROPANE GAS/HIGH ALTITUDE INSTALLATIONS

Requirements for propane gas and high altitude installations.

GAS VALVE

GAS PIPING CONNECTIONS

Guidelines for connecting gas piping to the furnace.

GAS PIPING CHECKS

DUCT WORK

CHECKING DUCT STATIC

FILTERS - READ THIS SECTION BEFORE INSTALLING THE RETURN AIR DUCT

ELECTRICAL CONNECTIONS

115 VOLT LINE CONNECTIONS

Procedures for making 115-volt line connections.

COOLCLOUD TM HVAC PHONE APPLICATION

GAS FURNACE TESTING

QUICK START GUIDE FOR GAS HEAT ONLY SETUP (No OUTDOOR UNIT)

ACCESSORIES

STARTUP PROCEDURE & ADJUSTMENT

FURNACE STARTUP

Step-by-step instructions for starting the furnace.

FURNACE SHUTDOWN

GAS SUPPLY PRESSURE MEASUREMENT

GAS MANIFOLD PRESSURE MEASUREMENT AND ADJUSTMENT

TEMPERATURE RISE

NORMAL SEQUENCE OF OPERATION

Description of normal power-up and heating operation sequences.

OPERATIONAL CHECKS

SAFETY CIRCUIT DESCRIPTION

Explanation of furnace safety circuits.

TROUBLESHOOTING

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

Precautions to prevent damage from static discharge.

RESETTING FROM LOCKOUT

Methods to reset the furnace from a lockout condition.

FILTER MAINTENANCE

CONDENSATE TRAP AND DRAIN SYSTEM (QUALIFIED SERVICER ONLY)

REPAIR AND REPLACEMENT PARTS

MENU OPTIONS

STATUS CODES

WIRING DIAGRAMS

Related product manuals