EasyManua.ls Logo

Amana RC17S2 - Invensy Control Service Test Modes

Amana RC17S2
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
Pad 5 Mode Name
Service Pad 5
Entry
Press Pad 5 while in Service Mode
Functional
Description
Auxiliary Output shall be toggled.
Display
A u x . O
u
t p u t : O N
Pad 7
Mode Name
Service Pad 7
Entry
Press Pad 7 while in Service Mode
Functional
Description
Displays Tube Hours stored in EEPROM
Display
M a g n e t r
o n H o u r S
0 0 1 7 4 3
Pad 8
Mode Name
Service Pad 8
Entry
Press Pad 8 while in Service Mode
Functional
Description
Displays Door Cycles stored in EEPROM. Will always be a multiple of
ten.
Display
D o o r
C y c l e s
0 0 2 4 5 3 8 0
Pad 9
Mode Name
Service Pad 9
Entry
Press Pad 9 while in Service Mode
Functional
Description
Prompts user to clear service information.
Display
P r e s s S
T A R T t o
C l e a r s e r v . i n f o
Pad 0 Mode Name Service Pad 0
Entry Press Pad 0 while in Service Mode
Functional
Description
Prompts user that CALL SERVICE alarm is cleared.
Display
C A L L S E R V I C E
A l a r m C l e a r e d