RS5290000 Rev. 0 28 April 1998
Electronic Functional Description
To avoid electrical shock which can cause severe personal injury or death, disconnect power to refrigerator using
power switch before servicing. Discharge capacitors through a resistor before handling. Wires removed during
disassembly must be replaced on proper terminals to insure correct earthing and polarization. After servicing,
reconnect power using power switch.
E10 E11 E12
E9
E8
E7
E6
E4
E3
E2
E1
R10
D11
X
X
W1
NEUTRAL (L2)
FREEZER DOOR OPEN
REFRIGERATOR DOOR OPEN
DEFROST HEATER RELAY
COMP/COND FAN RELAY COIL
DEFROST HEATER RELAY COIL
EVAPORATOR FAN RELAY COIL
DAMPER HEATER
12 PIN CONNECTOR
XX
X
X
LINE VOLTAGE
L1
EARTH
RELAY COILS
COMP/COND
FAN RELAY
DEFROST
RELAY
EVAP FAN
RELAY
COIL
TERMINALS
SWITCH
TERMINALS
WARNING