14
EN
Problem Cause / Solution
The product makes
a loud noise during
operation.
• The air filter is clogged.
• The product is tilted instead of staying upright
as it should be.
• The floor surface is not leveled.
Water on floor • The drain hose connection may be loose.
• The drain hose outlet (P) might be opened.
Error code Cause / Solution
AS • Humidity sensor error.
• Bring the product to a repair service.
ES • Temperature sensor error.
• Bring the product to a repair service.
P2 • Water container is full.
• Empty the bucket.
• Water container is not placed properly.
• Rearrange the water container until it fits
properly in the housing.
Specifications
B07XHQQ95Y
Rated voltage: 115 V~, 60Hz, single phase
Rated current: max. 7.8 A
Power input: max. 810 W
Standby power: 1 W
Moisture removal: 50 pints/day (23.66 L/day)
R.H. range: 35 – 85 % R.H.
Rated IEF: 0.48 gal/kWh (1.8 L/kWh)
Water tank capacity: 1.59 gal (6 L)
Refrigerant: R410A, 7.4 oz (210 g)
Fan IP rating: IP04
Power cord and plug: 3- wire; grounded
Air flow: 11301/13066 cft/h (320/370 m
3
/h)
Sound emission: ≤54 dB(A)