9
EN
Button Function
Filter (F)
• After approx. 250 hours of operation, the indicator
over the filter button lights up to remind the user to
clean the filter.
• After cleaning the filter, press and hold the filter
button for 3seconds to switch the filter indicator off
and to zero the filter counter.
Continuous
operation
(G)
• Press to toggle between continuous operation and
operation on demand.
• Button indicator on - Continuous operation:
Theproduct operates continuously and absorbs
asmuch humidity as possible.
• Button indicator off - Operation on demand: Set
manually the desired room humidity with the < >
buttons (J). The setting is shown on the display (D).
The adjustable value is 35% RH to 85% RH.
– After no button was pressed for 5seconds,
thesetting is saved and the display (D) switches
tothe actual room humidity.
– The product switches off, when the desired room
humidity is undercut by 1 %.
– The product switches on, when the desired room
humidity is exceeded by 5 %.
Turbo (H)
• Press to increase the fan speed for a faster room air
circulation. The button indicator lights up.
• Press again to set the fan speed to normal speed.
The button indicator goes off.
Timer (I)
• Set a timer when the product will switch on or off.
Press the button to toggle between the on and the
off timer. Which timer is actually selected is shown by
the timer indicators (C).
on timer
off timer
• Set the timer with the < > buttons (K). The setting
is shown on the display (D). The adjustable value is
0.5hour to 24hours.
(Continue on next page)