Technical Information
49
MBRELL
-
-
Precision Induction Heating
Command set
This table gives examples of each command’s use and the range of the data you can use
in the command ‘argument’. The address is required and the commas between the
address, command and arguments are required; do not insert spaces! Input is not case-
sensitive.
Each command must be arranged like this:
The multi-line data display (data) looks like this:
2-line display is arranged like this:
csv data arranged per this example:
the ‘setting’ if required
from the table below
device address (default=1); 1-32 available
0 = broadcast
address all
address,command,argument
header:
SETPOINT AMPS OUT POWER OUT FREQUENCY TIMER [CR/LF]
data:
1200.0A 0.0A 0W 0kHz 0ms [CR/LF]
PS# 1
Heat On (OFF)
Setpoint xx V
Amps Out x.x A
Power Out xx W
Frequency xx kHz
Timer xx ms
HeatOn xx
address heating setpoint amps watts frequency timer counter [CR/LF]
1 0 1200.0 10 3 140 1826 214 [CR/LF]
heating 0=off, 1=on; some fields may be blank
Example csv output string
1,0,1200.0,10,3,140,1826,214