NO GASSING
In order to properly opportunity or fast charge a battery, it must
be prevented from charging above 80% battery capacity more
than once per day.
We do this by adding timers that will prevent gassing for a pro-
grammed amount of hours, No Gassing Time.
It can be set to a timer with the Time (HH:MM) box.
It can be set to block out a period of time by entering the start
and end of that period in the Start and End Time boxes.
1x/day Full Charge
This feature will prevent more than one full charge a day regard-
less of how the charger is programmed.
BATTERY WATERING
This feature is to enable a battery watering indicator. It can be set
to let the user know when it is to be watered.
MOUNTING PATTERN
This is an excerpt from the 199740 and 199752 outline drawings.
Please request if you need further mechanical information (utilize
a 3/8" or 9.5 mm drill bit) The fasteners are M8 -1.25 with a max-
imum thread depth of 7.5mm. Please consider your rack or shelf
thickness as well as your washer thickness when selecting an
appropriate length
Note: remember to maintain 12" of free airspace between and in
front of each charger
Mounting pattern should be 4.53" (115 mm) square.