Sequoia / Tahoe Series User Manual California Instruments
92 M447352-01 REV-A
1
External
Reference
Signal - A
Analog
Input
±10V
Analog programming signal input terminal for
user-selectable external waveform programming
or amplitude control (RPV) for Phase-A.
2
External
Reference
Signal - B
Analog
Input
±10V
Analog programming signal input terminal for
user-selectable external waveform programming
or amplitude control (RPV) for Phase-B.
3
External
Reference
Signal - C
Analog
Input
±10V
Analog programming signal input terminal for
user-selectable external waveform programming
or amplitude control (RPV) for Phase-C.
4 ISO_COM Return Return
Common Ground: Pins 4, 9, and 14 are
internally connected.
5 N/C N/C N/C N/C
6
Output Current
Monitor - A
Analog
Output
±10V
Signal outputs for output phase A for monitoring
the waveform of the command signal of the
output amplifier.
7
Output Current
Monitor - B
Analog
Output
±10V
Signal outputs for output phase B for monitoring
the waveform of the command signal of the
output amplifier.
8
Output Current
Monitor - C
Analog
Output
±10V
Signal outputs for output phase C for monitoring
the waveform of the command signal of the
output amplifier.
9 ISO_COM Return Return
Common Ground: Pins 4, 9, and 14 are
internally connected.
10 N/C N/C N/C N/C
11
Output Voltage
Monitor - A
Analog
Output
±10V
Signal outputs for output phase A for monitoring
the waveform of the command signal of the
output amplifier.
12
Output Voltage
Monitor - B
Analog
Output
±10V
Signal outputs for output phase B for monitoring
the waveform of the command signal of the
output amplifier.
13
Output Voltage
Monitor - C
Analog
Output
±10V
Signal outputs for output phase C for monitoring
the waveform of the command signal of the
output amplifier.
14 ISO_COM Return Return
Common Ground: Pins 4, 9, and 14 are
internally connected.
15 N/C N/C N/C N/C
Table 4-2: External Analog Control Signal Connector Pinout
4.3.1 External Analog Programming of Output Voltage Waveform (Source and Grid-Simulator
MODE)
NOTE: This function is available in both the SEQUOIA and TAHOE series power supply and for the
SEQUOIA series, this function is applicable only in SOURCE and Grid-Simulator Modes of operation.