Sequoia / Tahoe Series User Manual California Instruments
102 M447352-01 REV-A
7. Navigate to the DASHBOARD screen and press on the SYNC button to start synchronizing
between Sequoia and EUT. Once Synchronization is successful, the SYNC button will display
SYNCED with a green color background.
8. The output could be turned on with the front panel OUTPUT switch.
eLoad Mode: Power Programming (Applicable only for Sequoia series)
1. Navigate to the PHASE NUMBER menu in the CONFIGURATION screen and select the output
phase number: either One-Phase or Three-Phase.
2. Navigate to the MODE menu in the CONFIGURATION screen and select the output voltage mode:
either AC or DC.
3. Navigate to the RANGE menu in the CONFIGURATION screen and select the output range: either
Low-Range or High-Range.
4. Navigate to the ACTIVE POWER menu in the OUTPUT PROGRAM screen and adjust the Active
Power value.
5. Navigate to the REACTIVE POWER menu in the OUTPUT PROGRAM screen and adjust the
Reactive Power value.
6. Navigate to the SYNC Settings menu in the CONFIGURATION screen and adjust the Sync
Voltage, Sync Phase, and Sync Frequency values.
7. Navigate to the DASHBOARD screen and press on the SYNC button to start synchronizing
between Sequoia and EUT. Once Synchronization is successful, the SYNC button will display
SYNCED with a green color background.
8. The output could be turned on with the front panel OUTPUT switch.
eLoad Mode: RLC Programming (Applicable only for Sequoia series)
1. Navigate to the PHASE NUMBER menu in the CONFIGURATION screen and select the output
phase number: either One-Phase or Three-Phase.
2. Navigate to the MODE menu in the CONFIGURATION screen and select the output voltage mode:
either AC or DC.
3. Navigate to the RANGE menu in the CONFIGURATION screen and select the output range: either
Low-Range or High-Range.
4. Navigate to the RLC menu in the OUTPUT PROGRAM screen and adjust the Resistance,
Inductance, and Capacitance value.
5. Navigate to the SYNC Settings menu in the CONFIGURATION screen and adjust the Sync
Voltage, Sync Phase, and Sync Frequency values.
6. Navigate to the DASHBOARD screen and press on the SYNC button to start synchronizing
between Sequoia and EUT. Once Synchronization is successful, the SYNC button will display
SYNCED with a green color background.
7. The output could be turned on with the front panel OUTPUT switch.
5.4 Front Panel Touch-Screen Display
The front panel display of the Sequoia/Tahoe Series power source allows the user to select the various
menus required to configure and operate the unit in Source mode, Grid Simulator, and E-Load. The
operating modes are explained in detail in the following separate sections. This section explains the