Sequoia / Tahoe Series User Manual California Instruments
158 M447352-01 REV-A
Figure 5-92. Regenerative Control Settings
PHASE NUMBER Programs the output phase configuration: One-Phase or
Three-Phase. The default is Three-Phase.
Figure 5-93. Phase Number Settings
WAVEFORM Selects the waveform for the output voltage: either standard
waveforms for sine wave, square wave, clipped-sine wave, or
user-defined waveforms; The default is a sine wave.
The standard waveforms are always available, and do not
consume any of the user-defined waveform memory registers;
they are always displayed in the waveform list. The clipped-sine
waveform has a waveform where the peak amplitude of the
positive and negative alternation is clipped (flattened
appearance). The level of clipping is dependent on the amount of
harmonic distortion present in the output waveform. An additional
programmable parameter, CLIP % THD, is available for setting
the percentage of total harmonic distortion (THD); the range is 0-
43%.