Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 167
PONS REGULATION Selects either Current-Limit mode (CL), where the output would
be shut down when the current reaches the set value, or
Constant-Current mode (CC), where the output current would be
regulated when it reaches the set value; the default is Current-
Limit
Figure 5-111.PONS Regulation menu
PONS OUTPUT PONS menu: Selects whether the output is turned on or off when
the unit is powered up. If output-on is selected, the output voltage
will be programmed to the value sets in the PONS VOLTAGE
sub-menu; the default is off.
Figure 5-112. PONS Output Settings
PONS VOLTAGE SENSE PONS menu: Selects the point for the sensing of the output
voltage for regulation, either Internal (local, at the rear panel
terminals) or External (remote, through the Remote Sense
connection to the load); the default is External.