Sequoia / Tahoe Series User Manual California Instruments
180 M447352-01 REV-A
The VOLTAGE DROP sub-menu has the following fields:
Entry Description
T(ime) Sets the time, in seconds or cycles, that the output voltage will
dwell at zero.
Rep(ea)t Sets the number of times the sweep/step transient event will be
repeated before execution will proceed to the next event or exit
the transient list. The number of times the transient event is
generated is equal to the value, REPEAT+1. The value should
be zero if only one execution of this event in the list is desired.
Trig(ger) Causes a trigger pulse to be generated for the selected event
when LIST is selected for Trig(ger) Out Source in the SETTINGS
menu.
Delay Sets the time duration, in seconds or cycles, that the voltage
amplitude will stay at the previous level (before the drop to zero),
before the next transient event is executed, or the transient list is
completed.
Save Completes the transient editing. All data fields should be entered
before saving. The event number is automatically set based on
the selection of either BEFORE or AFTER in the LIST menu and
will be a value between 0 and 99. The event number determines
the order of execution of the transient events in a multiple-event
transient.
Phase Displays the phases that had been selected in the Settings menu.
5.8.6.4 CURRENT SWEEP/STEP Sub-Menu
The CURRENT SWEEP/STEP menu allows changing the current during a transient. A current sweep is a
continual change that takes place over a period of time, while during a current step, the change occurs at
the maximum slew rate. When the transient definition is complete, tap SAVE to store the transient step
settings in non-volatile memory and return to the ADD menu.
Figure 5-138. LIST Menu, CURRENT SWEEP/STEP Sub-Menu
The CURRENT SWEEP/STEP sub-menu has the following fields: