Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 211
5.10.4 Output Program Screen
The OUTPUT PROGRAM screen provides the settings of output-related items such as individual output
parameters, mode of regulation and current limit, output waveform selection, and display of real-time output
waveform or harmonics spectrum.
The top-level menus of the OUTPUT PROGRAM screen are shown in Figure 5-199. They could be
reached in one of two ways:
1. Tapping the OUTPUT PROGRAM screen on the HOME Screen of the front panel touch-screen.
2. Scrolling to the OUTPUT PROGRAM screen with the encoder and depressing the encoder switch.
The UP arrow button will return to the previously selected screen menu (in this case the HOME Screen).
The HOME button will return to the HOME screen that has the top-level menu for the sub-menu being
displayed; for the OUTPUT PROGRAM screen top-level menu, that is the HOME Screen.
Figure 5-199. OUTPUT PROGRAM Screen Top-Level Menu
The following choices are available in the OUTPUT PROGRAM screen top-level menu. Functions that
accept a numeric value require that the value is within the allowed range, otherwise, an error will be
generated, and the value will not be accepted.
Entry Description
Settings
RLC Users can program the Resistance, Inductance and Capacitance
required as a load for the UUT. To adjust the settings, the user
must input a value for R, L, or C and then press the apply button
for the configured value to be programmed. Only if there is a
change in Resistance, Inductance, or Capacitance, APPLY
button will be enabled, for the user to configure the settings. Refer
to Figure 5-197. If there is no change APPLY button will be
disabled.