Harmonics Bar View:  This function displays the frequency spectrum of the output 
voltage or current waveform derived through FFT (fast Fourier 
transform) analysis. The frequency spectrum is displayed in 
graphical format, ranging from DC through the 49
th
 harmonic, with 
up to 25 harmonic components shown per screen; refer to Figure 
5-237. Individual harmonics could be selected (shown with a 
triangle along the horizontal axis) to display their parameter data 
using the Right and Left arrow buttons, touch-screen, or encoder. 
The upper right side presents the data for the selected harmonic: 
harmonic number, frequency, percentage of fundamental, and 
phase angle). Refer to Section 6.2.2 for additional information on 
the harmonics graphical view.  
 