Number Message String Cause Remedy
-128 “Numeric data not allowed” The number received, but
not allowed
Check the Programming Manual for
correct command syntax.
-168 “Block data not allowed” Block data received but not
allowed
Check the Programming Manual for
correct command syntax.
-200 “Execution error” The command could not be
executed
The command might be inconsistent
with the mode of operation, such as
programming frequency when in
DC-Mode.
-201 “Invalid while in local” Command issued but the
unit is not in the remote
state
Put the instrument in the remote state
before issuing SCPI commands.
-203 “Command protected” The command is locked out Some commands are supported by the
unit but are locked out for the protection
of settings and are not user accessible.
-210 “Trigger error” Problem with the trigger
system
The unit could not generate a trigger for
transient execution or measurement.
-211 “Trigger ignored” Trigger request has been
ignored
The trigger setup was incorrect or the
unit was not armed when the trigger
was received. Check transient system
or measurement trigger system
settings.
-213 “Init ignored” The initiation request has
been ignored
The unit was told to go to armed state
but was unable to do so. Could be
caused by an incorrect transient system
or measurement acquisition setup.
-220 “Parameter error” Parameter not allowed Incorrect parameter or parameter
value. Check the Programming Manual
for allowable parameters.
-221 “Setting conflict” Requested setting conflicts
with other settings in effect
Check settings: e.g., changing mode,
AC/DC/AC+DC, is not allowed with
output on; setting voltage is not allowed
if reference is not internal; setting
frequency is not allowed if set for
External SYNC or Clock/Lock.
-222 “Data out of range”
Parameter data outside of
the allowable range
Check the Programming Manual for
allowable parameter values.
-223 “Too much data”
More data received than
expected
Check the Programming Manual for the
number of parameters or data block
size.
-224 “Illegal parameter value” The parameter value is not
supported
Check the Programming Manual for
correct parameters.
-226 “Lists not same length” One or more transient lists
programmed had different
length
All lists must be of the same length or
transient cannot be compiled and
executed.
-254 “Media full” No storage space left to
save settings or data
Delete other settings or data to make
room.
-255 “Directory full” Too many waveform
directory entries
Delete one or more waveforms from
waveform memory to make room.
-256 “File name not found” Waveform requested is not
in the directory
Check the waveform directory for the
waveform names present.
-257 “File name error” Incorrect filename Check waveform file definition for too
many or non-ASCII characters.