Sequoia / Tahoe Series User Manual California Instruments
302 M447352-01 REV-A
10. Error and Status Messages
Errors that occur during operation from either the front panel or the remote digital interface will result in
error messages. Error messages are displayed on the front panel display and are also stored in memory
allocated to the error message queue. The error messages in the queue could be read using the SCPI
query command, SYST:ERR?. The error queue has a finite depth; if more error messages are generated
than can be held in the queue, a queue overflow message will be put in the last queue location. To empty
the queue, read out the error queue until the message, No Error, is received. Errors appearing on the front
panel display have a negative number and will generally remain visible until the user moves to another
screen. If multiple error messages are generated in succession, only the last message will be displayed.
Status messages give information on the operational state of the power source. They appear on the front
panel with a positive number.
The table below displays a list of possible error and status messages along with their possible cause and
remedy. Refer to the Sequoia Series Programming Manual, M447353-01 and Tahoe Series Programming
Manual P/N M445374-01 for more details.
Number Message String Cause Remedy
0 “No error” No errors in the queue Normal operation
-100 “Command error” Unable to complete the
requested operation
Check command syntax and data type.
-102 “Syntax error” SCPI command syntax
incorrect, unrecognized
command or data type
Correct command syntax, e.g.
misspelled or unsupported commands.
-103 “Invalid separator” SCPI command separator
not recognized
Check the SCPI section of the
Programming Manual.
-104 “Data type error” Command data element
invalid
Check the command for supported data
types.
-108 “Parameter not allowed” One or more additional
command parameters were
received
Check the Programming Manual for the
correct number of parameters.
-109 “Missing parameter” Too few command
parameters were received
for the requested operation
Check the Programming Manual for the
correct number of parameters.
-110 “Command header error” Command header incorrect Check the syntax of the command.
-111 “header separator error” Invalid command separator
used.
Ensure that a semi-colon is used to
separate command headers.
-112 “Program mnemonic too
long”
Command syntax error Check the Programming Manual for
correct command syntax.
-113 “Undefined header” Command not recognized
error
Check the Programming Manual for
correct command syntax.
-120 “Numeric data error” Data received is not a
number
Check the Programming Manual for
correct command syntax.
-121 “Invalid character in number” The number received
contains a non-numeric
character(s)
Check the Programming Manual for
correct command syntax.
-123 “Exponent too large” The number exponent
exceeds the limits
Check the Programming Manual for
correct command syntax.