Sequoia / Tahoe Series User Manual California Instruments
14 M447352-01 REV-A
2.9 Output current limit characteristics – Constant Power Mode
Operation at higher currents but constant power is possible from 72% of Voltage range (138% of max.
current) declining to 100% of maximum current at 100 % of voltage range.
Output current limit
characteristics are applicable for Source and Sink operating Modes, Refer to Figure 2-4. Full-scale current
rating for different power models is given in Table 2-1.
Figure 2-4: Output current limit characteristics- Constant Power Mode
Model
No of
chassis
Output Power
(KVA)
AC mode, DC
mode and
AC+DC mode
Output Current,
Full-Scale (per phase)
AC mode and AC+DC
mode
DC mode Output Current,
Full-Scale (per phase)
RMS (A)
Low - 166V
RMS (A)
High - 333V
RMS (A)
Low - 220 V
RMS (A)
High - 440V
RMS (A)
SQ0022/
TA0022
1
22.5 62.5 31.25 47 23.5
SQ0030/
TA0030
1
30 83 41.5 62.6 31.3
SQ0045/
TA0045
1
45 125 62.5 94 47
SQ0090/
TA0090
2 x SQ0045
2 x TA0045
1 x SQ0090
1 x TA0090
90 250 125 188 94
SQ0135/
TA0135
3 x SQ0045
3 x TA0045
135 375 187.5 282 141
SQ0180/
TA0180
2 x SQ0090
2 x TA0090
180 500 250 376 188
SQ0270/
TA0270
3 x SQ0090
3 x TA0090
270 750 375 564 282