Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 31
2.30 Firmware/Software Options
Option
1
Description
AVSTD, (MC)
Avionics Electrical Power Quality Test Software Package.
includes 160 (RTCA/DO160 E/F/G), 704 (MIL-STD 704 A/B/C/D/E/F),
ABD (Airbus ADB100.1.8 D/E), A350 (Airbus ADB100.1.8.1 B/C).
AVALL, (MC)
Avionics Electrical Power Quality Test Software Package; includes AVSTD,
B787 (Avionics Electrical Power Quality Test Software; Boeing 787B3-0147 A/B/C)
AMD (Avionics Electrical Power Quality Test Software; Airbus AMD24 C)
MIL1399, (MC) Interface Standard for Shipboard Systems Electric Power, Alternating Current
MIL1399+ AVSTD, (MC)
Interface Standard for Shipboard Systems Electric Power, Alternating Current
Avionics Electrical Power Quality Test Software Package.
includes 160 (RTCA/DO160 E/F/G), 704 (MIL-STD 704 A/B/C/D/E/F),
ABD (Airbus ADB100.1.8 D/E), A350 (Airbus ADB100.1.8.1 B/C).
MIL1399+ AVALL, (MC)
Interface Standard for Shipboard Systems Electric Power, Alternating Current
Avionics Electrical Power Quality Test Software Package; includes AVSTD,
B787 (Avionics Electrical Power Quality Test Software; Boeing 787B3-0147 A/B/C)
AMD (Avionics Electrical Power Quality Test Software; Airbus AMD24 C)
MC Options are installed in all chassis of a multi-chassis (MC) configuration
1
For Avionics options, reference the Avionics Software Manual (P/N 4994-971) for test details. All options require
the use of the provided Virtual Panels, graphical user interface Windows application software (reference CD ROM
CIC496).
2.31 XVC - 444 Option Specifications
The –XVC option provides an AC only output range of 0 to 444 Vac L-N. Common specifications for all
models are given in Table 2-10. Current ratings for different power models for 3-phase and 1-phase mode
are in Table 2-11 and Table 2-12 respectively. In -XVC option range only Source and SINK-grid simulator
operating modes are supported (SINK-Electronic Load operating mode is not supported). Output current
limit characteristics are shown in Figure 2-5.
All Models
Working mode AC Mode
AC Output phase Voltage 0 – 444 V
Voltage Resolution 0.1 V
Voltage Programming
Accuracy
± 0.25% of Full Scale
Output Coupling AC coupled
Frequency range with Standard option: 45 Hz – 550 Hz
with –HF option: 45 Hz – 905 Hz (see also –HF
option specification.)
Table 2-10: Common Output electrical specifications for XVC – 444V option
Model
No of
chassis
Output Power (KVA) AC mode Output Current,