are in Table 2-14 and Table 2-15 respectively. In -XVC option range only Source and SINK-grid simulator
operating modes are supported (SINK-Electronic Load operating mode is not supported). Output current
limit characteristics are shown in Figure 2-5.
All Models
Working mode AC Mode
AC Output phase Voltage 0 – 555 V
Voltage Resolution 0.1 V
Voltage Programming
Accuracy
± 0.25% of Full Scale
Output Coupling AC coupled
Frequency range with Standard option: 45 Hz – 550 Hz
with –HF option: 45 Hz – 905 Hz (see also –HF
option specification.)
Table 2-13: Common Output electrical specifications for XVC-555 V option
Model
No of
chassis
Output Power (KVA) AC mode Output Current,
Full-Scale ( Per Phase)
AC mode RMS (A) Peak (A)
SQ0090/
TA0090
2 x SQ0045 /
2 x TA0045
1 x SQ0090
1 x TA0090
90 54 162
SQ0180/
TA0180
2 x SQ0090
2 x TA0090
180 108 324
SQ0270/
TA0270
3 x SQ0090
3 x TA0090
270 162 486
SQ0360/
TA0360
4 x SQ0090
4 x TA0090
360 216 648
SQ0450/
TA0450
5 x SQ0090
5 x TA0090
450 270 810
SQ0540/
TA0540
5 x SQ0090
5 x TA0090
540 324 972
Table 2-14: Phase output Current and Power specifications for -XVC 555 option-Three
phase
Model
No of
chassis
Output Power
(KVA)
AC mode Output Current,
Full-Scale (Per Phase)
AC mode RMS (A) Peak (A)
SQ0090/
TA0090
1 90 162 486
Table 2-15: Phase output Current and Power specifications for -XVC 555 option-Single
phase