Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 61
safety isolation SELV-rated, referenced to chassis;
Isolated Output
Voltage
Monitor Outputs
Signal outputs for each output phase for monitoring the waveform of the command signal
of the output amplifier;
0-7.07V(RMS) signal range for zero to full-scale output voltage;
Isolated Output
Current
Monitor Outputs
Signal outputs for each output phase for monitoring the waveform of the command signal
of the output amplifier;
0-7.07V(RMS) signal range for zero to full-scale output voltage;
Table 3-20: External Analog Control Functions
Pin # Name Type Range Function
1
External
Reference
Signal - A
Analog
Input
0-7.07 V(RMS)
or 0 – 10 VDC
Analog programming signal input terminal for
user-selectable external waveform programming
or amplitude control (RPV) for Phase-A.
2
External
Reference
Signal - B
Analog
Input
0-7.07 V(RMS)
or 0 – 10 VDC
Analog programming signal input terminal for
user-selectable external waveform programming
or amplitude control (RPV) for Phase-B.
3
External
Reference
Signal - C
Analog
Input
0-7.07 V(RMS)
or 0 – 10 VDC
Analog programming signal input terminal for
user-selectable external waveform programming
or amplitude control (RPV) for Phase-C.
4 ISO_COM Return Return
Common Ground: Pins 4, 9, and 14 are
internally connected.
5 N/C N/C N/C N/C
6
Output Current
Monitor - A
Analog
Output
0-7.07 V(RMS)
Signal outputs for output phase A for monitoring
the waveform of the command signal of the
output amplifier.
7
Output Current
Monitor - B
Analog
Output
0-7.07 V(RMS)
Signal outputs for output phase B for monitoring
the waveform of the command signal of the
output amplifier.
8
Output Current
Monitor - C
Analog
Output
0-7.07 V(RMS)
Signal outputs for output phase C for monitoring
the waveform of the command signal of the
output amplifier.
9 ISO_COM Return Return
Common Ground: Pins 4, 9, and 14 are
internally connected.
10 N/C N/C N/C N/C
11
Output Voltage
Monitor - A
Analog
Output
0-7.07 V(RMS)
Signal outputs for output phase A for monitoring
the waveform of the command signal of the
output amplifier.
12
Output Voltage
Monitor - B
Analog
Output
0-7.07 V(RMS)
Signal outputs for output phase B for monitoring
the waveform of the command signal of the
output amplifier.